ILME Catalog

dimensions shown in mm are not binding and may be changed without notice 271 i MIXO INSERTS 34 14,7 44,3 39 M F - male and female contacts finger proof WKHLU NH\ FKDUDFWHULVWLF lies in the fact that they guarantee maximum safety even in case of accidental contact with fingers (IP2X or IPXXB) . 6DIHW\ LV JXDUDQWHHG DV VWDQGDUG RQ IHPDOH FRQWDFWV but also on male contacts 7KLV IHDWXUH LV LPSRUWDQW DV LW HQVXUHV IXOO FRPSOLDQFH ZLWK WKH UHFHQW VDIHW\ standard EN 60204-1 , concerning electric equipment fitted on machines and in particular with the requirements of Article 6.2.4 concerning protection against residual voltage. In the case of plugs or similar devices, the with drawal of which results in the exposure of conductors (for example pins), the discharge time shall not exceed 1 s, otherwise such conductors shall be protected against direct contact to at least an IP2X or IPXXB. MIXO modular units CX 3/4 XDF/XDM 3 poles (40A - 830V) + 4 poles (10A - 830V) modular units, crimp connections 40A and 10A crimp contacts silver and gold plated 40A 10A description part No. part No CXF and CXM 23,5 29,1 B B ø 4 ø A ø 6 ø A ø 6 CDF and CDM ø 1,6 ø A ø 3,2 B ø A ø 3,5 21,6 25 B CXF and CXM contacts conductor conductor conductors section slot stripping length (mm 2 ) ø A (mm) B (mm) 1,5 1,8 9 2,5 2,2 9 4 2,85 9,6 6 3,5 9,6 CDF and CDM contacts 0,14-0,37 0,9 8 0,5 1,1 8 0,75 1,3 8 1,0 1,45 8 1,5 1,8 8 2,5 2,2 6 - characteristics according to EN 61984: 3 poles 40A 830V 8kV 3 4 poles 10A 830V 8kV 3 - (UL for USA and Canada), certified - rated voltage according to UL/CSA: 600V LQVXODWLRQ UHVLVWDQFH • *ȍ - ambient temperature limit: -40 °C ... +125 °C - made of self-extinguishing thermoplastic resin UL 94V-0 PHFKDQLFDO OLIH • F\FOHV FRQWDFW UHVLVWDQFH ” Pȍ SROHV ” Pȍ SROHV - for max. current load see the connector inserts derating diagram below; for more information see page 28 10 20 30 40 50 60 70 80 90 100 110 0 120 130 0 20 40 50 30 10 5 25 15 35 4,0 mm 2 6,0 mm 2 2,5 mm 2 1,5 mm 2 ambient temperature (°C) working current (A) CX 3/4 XD, 3/4 poles connector inserts Maximum current load derating diagram 2 2 1 3 1 3 F M - 1 frame slot contacts side (front view) side with reference arrow ▲ The modular inserts must be installed in suitable frames which are then mounted in traditional enclosures or in COB panel support. Single-sized modular units may be directly mounted inside MIXO ONE enclosures. page: frames for modular units 316 - 317 MIXO ONE enclosures 369 ZLWKRXW FRQWDFWV WR EH RUGHUHG VHSDUDWHO\ female inserts for female contacts CX 3/4 XDF male inserts for male contacts CX 3/4 XDM 40A female crimp contacts 1,5 mm 2 $:* CXFA 1.5 2,5 mm 2 $:* CXFA 2.5 4 mm 2 $:* CXFA 4.0 6 mm 2 $:* CXFA 6.0 40A male crimp contacts 1,5 mm 2 $:* CXMA 1.5 2,5 mm 2 $:* CXMA 2.5 4 mm 2 $:* CXMA 4.0 6 mm 2 $:* CXMA 6.0 10A female crimp contacts 0,14-0,37 mm 2 $:* LGHQWLILFDWLRQ 1R CDFA 0.3 CDFD 0.3 0,5 mm 2 $:* LGHQWLILFDWLRQ 1R CDFA 0.5 CDFD 0.5 0,75 mm 2 $:* LGHQWLILFDWLRQ 1R  CDFA 0.7 CDFD 0.7 1 mm 2 $:* LGHQWLILFDWLRQ 1R CDFA 1.0 CDFD 1.0 1,5 mm 2 $:* LGHQWLILFDWLRQ 1R CDFA 1.5 CDFD 1.5 2,5 mm 2 $:* LGHQWLILFDWLRQ 1R CDFA 2.5 CDFD 2.5 10A male crimp contacts 0,14-0,37 mm 2 $:* LGHQWLILFDWLRQ 1R CDMA 0.3 CDMD 0.3 0,5 mm 2 $:* LGHQWLILFDWLRQ 1R CDMA 0.5 CDMD 0.5 0,75 mm 2 $:* LGHQWLILFDWLRQ 1R  CDMA 0.7 CDMD 0.7 1 mm 2 $:* LGHQWLILFDWLRQ 1R CDMA 1.0 CDMD 1.0 1,5 mm 2 $:* LGHQWLILFDWLRQ 1R CDMA 1.5 CDMD 1.5 2,5 mm 2 $:* LGHQWLILFDWLRQ 1R CDMA 2.5 CDMD 2.5 % for basic or high thickness gold plating, please refer to page 674 gold plated % silver plated - it is recommended to crimp the contacts with crimping tools homologated by ILME (please see the crimping tool section 40A contacts, CXF, CXM VHULHV DQG $ FRQWDFWV &') &'0 VHULHV on pages 708 - 741

RkJQdWJsaXNoZXIy MzUzMzk=