ILME Catalog

10.000 MATINGS WITH HNM FRAMES AND HNM ENCLOSURES 5.000 MATINGS WITH HNM FRAMES AND STANDARD ENCLOSURES , SINGLE LEVER dimensions shown in mm are not binding and may be changed without notice 325 i MIXO - HNM )HPDOH LQVHUWV DUH VXSSOLHG ZLWK WZR UHG ORFN WDE that must be used instead of those supplied with the frames. modular units, crimp connections 40A crimp contacts with red lock-in tab (included) gold plated description part No. part No 23,5 29,1 B B ø 4 ø A ø 6 ø A ø 6 RXF2D and RXM2D contacts conductor conductor conductor section slot stripping length (mm 2 ) ø A (mm) B (mm) 1,5 1,8 9 2,5 2,2 9 4 2,85 9,6 6 3,5 9,6 - characteristics according to EN 61984: 40A 830V 8kV 3 40A 1000V 8kV 2 - (UL for USA and Canada), certified - rated voltage according to UL/CSA: 600V - LQVXODWLRQ UHVLVWDQFH • *ȍ - ambient temperature limit: -40 °C ... +125 °C - made of self-extinguishing thermoplastic resin UL 94V-0 - PHFKDQLFDO OLIH • F\FOHV FRQWDFW UHVLVWDQFH ” Pȍ IRU VSDUH ORFN LQ WDE CX CFMX VHH 63$5( 63$576 catalogue - it is recommended to crimp the contacts with crimping tools homologated by ILME (please see the crimping tool section $ FRQWDFWV 5;) ' DQG 5;0 ' series) on pages 708 - 741 - for max. current load see the connector inserts derating diagram below; for more information see page 28 10 20 30 40 50 60 70 80 90 100 110 0 120 130 0 20 40 50 30 10 5 25 15 35 4,0 mm 2 6,0 mm 2 ambient temperature (°C) working current (A) CX 04 poles connector inserts Maximum current load derating diagram 1 2 3 4 F 1 2 3 4 M - 1 frame slot contacts side (front view)c side with reference arrow ▲ 34 14,7 46,8 42,9 M F The modular inserts must be installed in suitable frames, which are then mounted in traditional enclosures* or in COB panel supports. page: frames for modular units* 333 - male and female contacts finger proof WKHLU NH\ FKDUDFWHULVWLF lies in the fact that they guarantee maximum safety even in case of accidental contact with fingers (IP2X or IPXXB) . 6DIHW\ LV JXDUDQWHHG DV VWDQGDUG RQ IHPDOH contacts, but also on male contacts 7KLV IHDWXUH is important as it ensures full compliance with the UHFHQW VDIHW\ standard EN 60204-1 , concerning electric equipment fitted on machines and in particular with the requirements of Article 6.2.4 concerning protection against residual voltage. In the case of plugs or similar devices, the with drawal of which results in the exposure of conductors (for example pins), the discharge time shall not exceed 1 s, otherwise such conductors shall be protected against direct contact to at least an IP2X or IPXXB. HQFORVXUHV EXONKHDG PRXQWLQJ KRXVLQJV KLJK construction housings or high construction hoods ZLWKRXW FRQWDFWV WR EH RUGHUHG VHSDUDWHO\ PRGXOH UHG ORFN LQ WDE LQFOXGHG female inserts for female contacts CX 04 XF male inserts for male contacts CX 04 XM 40A female crimp contacts 1,5 mm 2 AWG 16 RXF2D 1.5 2,5 mm 2 AWG 14 RXF2D 2.5 4 mm 2 AWG 12 RXF2D 4.0 6 mm 2 AWG 10 RXF2D 6.0 40A male crimp contacts 1,5 mm 2 AWG 16 RXM2D 1.5 2,5 mm 2 AWG 14 RXM2D 2.5 4 mm 2 AWG 12 RXM2D 4.0 6 mm 2 AWG 10 RXM2D 6.0 gold plated MIXO HNM modular units CX 04 XF/XM 4 poles 40A - 830V HNM (High Number of Matings)

RkJQdWJsaXNoZXIy MzUzMzk=